Powerline to houses on Sunshine Coast

PeakSmart events

Every now and then, the network reaches a point of extreme stress, such as during a heat wave, when households and businesses across South East Queensland switch on their air conditioners at the same time. On these occasions, our innovative PeakSmart technologies are called on to help manage demand. We call this a PeakSmart event.

PeakSmart air-conditioners receive signals from our network when we experience unusually high demand. The signal tells the air-conditioner to drop into an energy efficient mode, similar to an economy setting.

South East Queensland's electricity network is robust, so PeakSmart events may only occur on a few occasions per year. The technology is designed to be 'set and forget' so you won't have to do anything or notice a difference to your comfort.

Demand Response Modes

There are a number of performance responses for signalling appliances. There are 3 Demand Response Modes (DRM) for air-conditioners, depending on how extreme the need for demand management becomes.

  1. DRM1: Compressor off
  2. DRM2: capped to operate at 50%
  3. DRM3: capped to operate at 75%

Our signals are also equipped to target specific regional groups of air-conditioners, depending on areas of maximum need for demand management.

Events

See below the level and duration of recent events.

DateStartFinishDuration Demand Response Mode (DRM)
23 Jan 4:20pm 6:50pm 2 hours 30 minutes DRM2 - capped to operate at 50%
22 Jan 5:43pm 6:08pm 25 minutes DRM1 - compressor off was deployed to Jimboomba Substation area to reduce network load and minimise outages during extreme weather
22 Jan 4:20pm 6:50pm 2 hours 30 minutes DRM2 - capped to operate at 50%

DateStartFinishDuration Demand Response Mode (DRM)
28 Dec 4:20pm 6:50pm 2 hours 30 minutes DRM2 - capped to operate at 50%
27 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
8 Dec 6:00pm 12.00am 6 hours DRM1- compressor off was deployed to Logan Village Substation area to reduce network load and minimise outages during extreme weather
8 Dec 6:45pm 12.00am 5 hours 15 minutes DRM1- compressor off was deployed to Kingston and North McLean Substation area to reduce network load and minimise outages during extreme weather
8 Dec 7:15pm 12.00am 4 hours 45 minutes DRM1- compressor off was deployed to Redbank Plains Zone Substation area to reduce network load and minimise outages during extreme weather
8 Dec 8:20pm 12.00am 3 hours 40 minutes DRM1- compressor off was deployed to Cooneana, Yamanto and Ipswich South Zone Substation area to reduce network load and minimise outages during extreme weather
30 Aug 6:00pm 7:00pm 1 hour DRM2 - capped to operate at 50% for testing purposes in the North Maclean Area
13 Aug 3:49pm 6:00pm 2 hours 11 minutes DRM1- compressor off was deployed to Cooran Zone Substation area to reduce network load and minimise outages during extreme weather
27 Jan 4:20pm 6:50pm 2 hours 30 minutes DRM2 - capped to operate at 50%
22 Jan 4:20pm 6:50pm 2 hours 30 minutes DRM2 - capped to operate at 50%

Pre 2024

View all PeakSmart events prior to 2024.

2023

DateStartFinishDuration Demand Response Mode (DRM)
29 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
28 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
17 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
16 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
15 Dec 3:43pm 5:00pm 1 hour 17 minutes DRM1 - compressor off
Due to extreme weather events the DRM1 event was deployed to Staplyton Zone Substation area as essential operational requirement to manage overloads and mitigate outages
17 Mar 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
12 Feb 3:15pm 3:17pm 2 minutes DRM1 - compressor off for testing purposes
3 Feb 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%

2022

DateStartFinishDuration Demand Response Mode (DRM)
6 Jul 7:20pm 7:30pm 10 minutes DRM1 - compressor off for testing purposes
15 Jun 5:20pm 9:20pm 4 hours DRM2 - capped to operate at 50%
14 Jun 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
13 Jun 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
28 Feb 12pm 7:30pm 7.5 hours DRM1*

* Due to an extreme flooding scenario an extended DRM1 event was deployed to 4 localised zones as essential operational requirement to manage overloads and mitigate outages.
1 Feb 5:30pm 7:30pm 2 hours DRM2 - capped to operate at 50%

2021

DateStartFinishDuration Demand Response Mode
22 Feb 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%

2020

DateStartFinishDuration Demand Response Mode
2 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
19 Feb 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%

2019

DateStartFinishDuration Demand Response Mode
16 Dec 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
12 Mar 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
13 Feb 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%

2018

DateStartFinishDuration Demand Response Mode
21 Dec 3:30pm 5:30pm 2 hours DRM2 - capped to operate at 50%
15 Feb 4:30pm 6:30pm 2 hours DRM2 - capped to operate at 50%
14 Feb 4:30pm 6:30pm 2 hours DRM2 - capped to operate at 50%
13 Feb 4:30pm 6:30pm 2 hours DRM2 - capped to operate at 50%
12 Feb 4:30pm 6:30pm 2 hours DRM2 - capped to operate at 50%
11 Feb 4:30pm 6:30pm 2 hour DRM2 - capped to operate at 50%

2017

DateStartFinishDuration Demand Response Mode
13 Feb 3:25pm 6:25pm 3 hours DRM3 - capped to operate at 75%
12 Feb 5:30pm 7:30pm 2 hours DRM3 - capped to operate at 75%
25 Jan 4:10pm 5:10pm 1 hour DRM2 - capped to operate at 50%
20 Jan 4:10pm 6:10pm 2 hours DRM2 - capped to operate at 50%

2016

DateStartFinishDuration Demand Response Mode
2 Dec 3:00pm 5:30pm 2.5 hours DRM3 - capped to operate at 75%
4:00pm 6:30pm 2.5 hours DRM3 - capped to operate at 75%
2 Feb 4:30pm 5:30pm 1 hour DRM3 - capped to operate at 75%
1 Feb 4:30pm 5:30pm 1 hour DRM3 - capped to operate at 75%

2015

DateStartFinishDuration Demand Response Mode
20 Mar 5:30pm 7:00pm 1.5 hours DRM3 - capped to operate at 75%
19 Mar 5:30pm 7:00pm 1.5 hours DRM3 - capped to operate at 75%
5 Mar 3:30pm 5:00pm 1.5 hours DRM3 - capped to operate at 75%

2014

DateStartFinishDuration Demand Response Mode
9 Jul 6:00am 6:30am 30 min DRM3 - capped to operate at 75%
2 Jul 5:15pm 5:45pm 30 min DRM3 - capped to operate at 75%
17 Mar 3:00pm 4:00pm 1 hour DRM3 - capped to operate at 75%

2012

DateStartFinishDuration Demand Response Mode
4 Dec 5:30pm 7:30pm 2 hours DRM3 - capped to operate at 75%

For more information

Read our FAQs for find out more on PeakSmart events.