PeakSmart events

Every now and then, the network reaches a point of extreme stress, such as during a heat wave, when households and businesses across South East Queensland switch on their air conditioners at the same time. On these occasions, our innovative PeakSmart technologies are called on to help manage demand. We call this a PeakSmart event.

PeakSmart air-conditioners receive signals from our network when we experience unusually high demand. The signal tells the air-conditioner to drop into an energy efficient mode, similar to an economy setting.

South East Queensland's electricity network is robust, so PeakSmart events may only occur on a few occasions per year. The technology is designed to be 'set and forget' so you won't have to do anything or notice a difference to your comfort.

Demand Response Modes

There are a number of performance responses for signalling appliances. There are 3 Demand Response Modes (DRM) for air-conditioners, depending on how extreme the need for demand management becomes.

  1. DRM1: Compressor off
  2. DRM2: capped to operate at 50%
  3. DRM3: capped to operate at 75%

Our signals are also equipped to target specific regional groups of air-conditioners, depending on areas of maximum need for demand management.

Events

See below the level and duration of recent events.

DateStartFinishDurationDemand Response Mode (DRM)
8 Dec6:00pm12.00am6 hoursDRM1- compressor off was deployed to Logan Village Substation area to reduce network load and minimise outages during extreme weather
8 Dec6:45pm12.00am5 hours 15 minutesDRM1- compressor off was deployed to Kingston and North McLean Substation area to reduce network load and minimise outages during extreme weather
8 Dec7:15pm12.00am4 hours 45 minutesDRM1- compressor off was deployed to Redbank Plains Zone Substation area to reduce network load and minimise outages during extreme weather
8 Dec8:20pm12.00am3 hours 40 minutesDRM1- compressor off was deployed to Cooneana, Yamanto and Ipswich South Zone Substation area to reduce network load and minimise outages during extreme weather
30 Aug6:00pm7:00pm1 hourDRM2 - capped to operate at 50% for testing purposes in the North Maclean Area
13 Aug3:49pm6:00pm2 hours 11 minutesDRM1- compressor off was deployed to Cooran Zone Substation area to reduce network load and minimise outages during extreme weather
27 Jan4:20pm6:50pm2 hours 30 minutesDRM2 - capped to operate at 50%
22 Jan4:20pm6:50pm2 hours 30 minutesDRM2 - capped to operate at 50%

DateStartFinishDuration Demand Response Mode (DRM)
29 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
28 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
17 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
16 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
15 Dec3:43pm5:00pm1 hour 17 minutesDRM1 - compressor off
Due to extreme weather events the DRM1 event was deployed to Staplyton Zone Substation area as essential operational requirement to manage overloads and mitigate outages
17 Mar5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
12 Feb3:15pm3:17pm2 minutesDRM1 - compressor off for testing purposes
3 Feb5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%

Pre 2023

View all PeakSmart events prior to 2023.

2022

DateStartFinishDurationDemand Response Mode (DRM)
6 Jul 7:20pm 7:30pm 10 minutes DRM1 - compressor off for testing purposes
15 Jun 5:20pm 9:20pm 4 hours DRM2 - capped to operate at 50%
14 Jun 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
13 Jun 5:20pm 7:20pm 2 hours DRM2 - capped to operate at 50%
28 Feb 12pm 7:30pm 7.5 hours DRM1*

* Due to an extreme flooding scenario an extended DRM1 event was deployed to 4 localised zones as essential operational requirement to manage overloads and mitigate outages.
1 Feb 5:30pm 7:30pm 2 hours DRM2 - capped to operate at 50%

2021

DateStartFinishDurationDemand Response Mode
22 Feb5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%

2020

DateStartFinishDurationDemand Response Mode
2 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
19 Feb5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%

2019

DateStartFinishDurationDemand Response Mode
16 Dec5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
12 Mar5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%
13 Feb5:20pm7:20pm2 hoursDRM2 - capped to operate at 50%

2018

DateStartFinishDurationDemand Response Mode
21 Dec3:30pm5:30pm2 hoursDRM2 - capped to operate at 50%
15 Feb4:30pm6:30pm2 hoursDRM2 - capped to operate at 50%
14 Feb4:30pm6:30pm2 hoursDRM2 - capped to operate at 50%
13 Feb4:30pm6:30pm2 hoursDRM2 - capped to operate at 50%
12 Feb4:30pm6:30pm2 hoursDRM2 - capped to operate at 50%
11 Feb4:30pm6:30pm2 hourDRM2 - capped to operate at 50%

2017

DateStartFinishDurationDemand Response Mode
13 Feb3:25pm6:25pm3 hoursDRM3 - capped to operate at 75%
12 Feb5:30pm7:30pm2 hoursDRM3 - capped to operate at 75%
25 Jan4:10pm5:10pm1 hourDRM2 - capped to operate at 50%
20 Jan4:10pm6:10pm2 hoursDRM2 - capped to operate at 50%

2016

DateStartFinishDurationDemand Response Mode
2 Dec3:00pm5:30pm2.5 hoursDRM3 - capped to operate at 75%
4:00pm6:30pm2.5 hoursDRM3 - capped to operate at 75%
2 Feb4:30pm5:30pm1 hourDRM3 - capped to operate at 75%
1 Feb4:30pm5:30pm1 hourDRM3 - capped to operate at 75%

2015

DateStartFinishDurationDemand Response Mode
20 Mar5:30pm7:00pm1.5 hoursDRM3 - capped to operate at 75%
19 Mar5:30pm7:00pm1.5 hoursDRM3 - capped to operate at 75%
5 Mar3:30pm5:00pm1.5 hoursDRM3 - capped to operate at 75%

2014

DateStartFinishDurationDemand Response Mode
9 Jul6:00am6:30am30 minDRM3 - capped to operate at 75%
2 Jul5:15pm5:45pm30 minDRM3 - capped to operate at 75%
17 Mar3:00pm4:00pm1 hourDRM3 - capped to operate at 75%

2012

DateStartFinishDurationDemand Response Mode
4 Dec5:30pm7:30pm2 hoursDRM3 - capped to operate at 75%

For more information

Read our FAQs for find out more on PeakSmart events.